cleveland air conditioning contractor and heating and furnace repairs
Heating | Air Conditioning | Indoor Air Quality | Total Comfort Solution  | Comfort Club

 


national comfort instiute

serviceroundtable

 

Register To Receive Our Monthly Around the House Newsletter Full of home and money saving tips! Sign up today!

 

HVAC Home >> HVAC Resource Center >> Air Tightness

Measuring Air Tightness in Your Ohio Home

Despite the growing importance of house air tightness, few Ohio homeowners actually know how tight their homes are. Unfortunately, it is virtually impossible to accurately estimate the tightness level of a home by visual inspection alone. And without knowing house air tightness, it is difficult to assess the need for, or to design an effective approach to duct, air sealing & indoor air quality.

The easiest way to measure house air tightness is with a diagnostic tool called a blower door. The blower door consists of a powerful, calibrated fan that is temporarily sealed into an exterior doorway. The fan blows air out of the house to create a slight pressure difference between inside and outside. This pressure difference forces air through all holes and penetrations in the exterior envelope. Blower door tests are typically performed at a pressure difference of 50 Pa (0.2 inches of water column).

By simultaneously measuring the airflow through the fan and its effect on the air pressure in the house, the blower door system measures the air tightness of the entire building envelope. The tighter the building (e.g. fewer holes), the less air you need from the blower door fan to create a change in house pressure.

Air tightness measurements are presented in a number of different formats including:

square inches of leakage
air flow needed to generate 50 Pa of pressure difference (CFM50)
air changes per hour at 50 Pa of pressure difference (ACH50)

It takes about 20-40 minutes to set-up a blower door and do a test to document the air tightness of a house. In addition to assessing the overall air tightness level of the building envelope, the blower door can be used to estimate the amount of leakage between the conditioned space of the building and attached structural components such as garages, attics and crawlspaces. It can also be used to estimate the amount of outside leakage in forced air duct systems. And because the blower door forces air through all holes and penetrations, these problem spots are easier to find using chemical smoke, an infrared camera or simply feeling with your hand. The air tightness measurement can also help you assess the potential for back drafting of natural draft appliances by exhaust fans and other mechanical devices.

If you are looking for a Cleveland area HVAC Contractor, please call us today at (216) 214-0945 or complete our service request form.

 

 Service Areas | HVAC Articles | Free Newsletter | Request Service| Home Page

Design Air Heating & Cooling • 15874 Agnes Blvd
Brook Park, OH 44142
PHONE: (216) 214-0945 • FAX: (216) 267-6818
State Of Ohio License #27914

Cleveland Energy Audits

Preferred Local Vendors

©2007 Design Air Heating & Cooling. All Rights Reserved. No part of this site may be reproduced in any form without the copyright holder's written permission. HVAC Contractors

Areas We Provide HVAC Service In, Ohio

 Brook Park, OH, Middleburg Hts., OH, Strongsville, OH, Berea, OH, Cleveland, OH, Avon, OH, Avon Lake, OH, Bay Village, OH, Westlake, OH, North Olmsted, OH, North Royalton, OH, Parma, OH, Brooklyn, OH, Brecksville, OH, Broadview Hts., OH, Fairview Park, OH, Independence, OH, Lakewood, OH, Olmsted Falls, OH, Rocky River, OH, Seven Hills, OH